Portable Air Cleaners - Technical Data
 

RollOut Filter Unit Dimensions

L

[mm] /[in]

887/34.92

S

[mm] /[in]

742/29.21

H1

[mm] /[in]

922/36.30

H2

[mm] /[in]

1182/46.53

H3

[mm] /[in]

1400/55.12

D1

[mm] /[in]

160/6

D2

[mm] /[in]

195/7.68

n

[-]

6

d1

[mm] /[in]

M6

d2

G1/2" / 1/4 NPT

H (dla NZW/3-160)

[m]/[ft]

4.05/13.12

R (dla NZW/3-160)

[m]/[ft]

2.80/9.19



RollOut Filter Additonal Data

Motor Power

[kW]/[HP]

0,75/1

Rotation

1 /[min]

3450

Air tank

[l]

10

Air pressure

[atm]

5-6

Airflow with the arm

[m3/h] /[cfm]

1166/700

Airflow without the arm

[m3/h] /[cfm]

2000/1200

Preliminary filter
(spark trap)

[mm]
/[in]

540x440x20
21x17x0.8

Cartridge

[mm]
/[in]

325x660
12.8x26

Carbon afterfilter

[mm] /[in]

540x440x20
21x17x0.8



RollOut Airflow Diagram (metric)


RollOut Airflow Diagram (imperial)